home > sell > Twelve-lead synchronous dynamic electrocardiogram analysis system
Twelve-lead synchronous dynamic electrocardiogram analysis system
products: Views:15Twelve-lead synchronous dynamic electrocardiogram analysis system 
brand: ORY9900 TCD
price: 面议
MOQ:
Total supply: 100000 台
Delivery date: Shipped within 3 days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2015-07-08 08:00
 
Details
The twelve-lead automatic analysis and diagnosis function is the main function of the electrocardiograph. This automatic analysis and diagnosis function is the most basic and common function in electrocardiogram examination.
Automatically complete the accurate measurement of electrocardiogram characteristic parameters, with a total of up to multiple parameters. Such as interval time width wave group shape, etc.
Automatically identify various abnormal heart beats and abnormal heart rhythms, and provide accurate automatic diagnosis results with up to multiple diagnostic items. Including arrhythmias such as sinus rhythm, supraventricular rhythm, ventricular rhythm, atrial fibrillation, ventricular premature beats, supraventricular premature beats, etc. Pre-excitation syndrome, conduction block, myocardial infarction, atrioventricular hypertrophy abnormality, cardiac axis abnormality, etc.
Different for different genders age of patients, using different automatic analysis and diagnosis algorithms, clinical verification accuracy is as high as above
Software functions
Standard synchronized twelve-lead electrocardiogram
Customized synchronized twelve-lead electrocardiogram eighteen Lead ECG
ECG vector diagram
Time vector diagram
Heart rate variability analysis
Ventricular late potential
Dispersion analysis
Standard synchronized twelve leads Electrocardiogram

Provides mature automatic analysis and automatic diagnosis functions, and its high accuracy ensures that routine twelve-lead electrocardiogram examinations are fast and efficient



Self Define synchronized twelve-lead electrocardiogram and eighteen-lead electrocardiogram

Provide customized synchronized twelve-lead electrocardiogram. The doctor can arbitrarily select the position of the electrode ball and customize the lead name for electrocardiogram examination. Use this function , adding equal leads has diagnostic significance for suspected posterior wall myocardial infarction or right ventricular myocardial infarction



Electrocardiogram vector diagram

Time vector diagram

Heart rate variability analysis

Time domain

Frequency domain

Non-linear analysis
Ventricular late potential

Dispersion analysis


Multiple printing formats Synchronized twelve-lead ECG leading heartbeat + normal II lead ECG leading heartbeat ECG + parameter table, synchronized twelve-lead ECG, single-lead long-term ECG

Hardware features
ECG signal acquisition box port, only one cable at one end to connect to a desktop or laptop computer For data transmission and power supply, the other end is connected to the standard ECG lead wire, which is connected to the human body through the suction ball and limb clamp
The high-performance digital ECG preamplifier ensures the minimum noise of the ECG signal
The filtering functions are all implemented in software using digital filters to ensure that the ECG waveform is not distorted
It has electromagnetic and photoelectric multiple isolation and a high isolation voltage to ensure safe and reliable ECG collection and fully complies with standards
Preamplifier circuit It adopts a floating design and does not need to be connected to the ground wire. It can also collect interference-free ECG signals


Technical Parameters
The sampling frequency of ventricular late potential is, and other ECG examination items It is
Sampling accuracy bit
The input loop current of each input loop is not greater than
The input impedance between each input loop is not less than
The common mode rejection ratio is not less than
Withstand polarization voltage
Low frequency characteristic time constant is not less than
Equipment safety classification type
Equipment model type
Product registration number Beijing Drug Administration Approval No.
Execution Standard number/京